Orifice plate flow rate calculator
flow rate measurement calculator
Desktop App
Desktop full-featured version.
Free Trial AvailableRegistration
Select a fair price and enable the full service:
- Switch between metric and imperial units in one click
- Export calculation results in Word .docx or Excel .xlsx format
- Preview results on one place and copy/paste it in your favorite text editor
- Send results back to your email
- Support the future of this project
And even more... get access to the full set of 19 desktop calculators available for MacOS, Linux or Windows.
Full Year Service
Prepaid Monthly Cost
$2.50/month
Full year $29.95/year
Why should you use this calculator?
Use this calculator to quickly calculate the actual flow rate through the orifice plate flow meter with only a few inputs. This calculator performs the flow rate calculation from the measured pressure drop caused by the orifice plate inserted in the pipeline.
When is this calculator relevant?
The calculator is suitable for liquids and perfect gases, a subsonic flow of single phase fluid. It is not applicable for pulsating flow. The pipeline should be circular. The calculator is not applicable for rectangular ducts.
When is this calculator not relevant?
This calculator is not suitable for multiphase fluids, like a flow of liquids that contain solid particles or flow of liquids that contain undissolved gases. Also, it is not suitable for gases that are not ideal, i.e., gases that don't relate to the ideal gas law.
What has to be understood to perform the calculation?
To calculate flow rate, you have to enter the orifice plate throat diameter as well as pipe interior diameter, together with fluid properties - density and viscosity. For a gas as flowing fluid, instead of the density, you can enter gas constant, pressure and temperature at actual conditions. Density is then calculated using a perfect gas state equation. You should enter density on real flow conditions - pressure and temperature.
How is the calculation performed?
The calculator is doing calculation according to ISO 5167-2. You can expect to have correct and reliable results only if the orifice plate meets the conditions from the standard.
What are the standard ISO 5137-2 conditions?
For the flow of a perfect gas, the pressure loss created by the orifice must be higher than 0.75.
Orifice meters which have corner pressure tappings or D and D/2 pressure tappings must meet following conditions:
d > 12.5 mm
50 mm < D < 1000 mm
0.1 < β < 0.75
ReD > 5000 for 0.1 < β < 0.56
ReD > 16000xβ2 for β > 0.56
Orifice meters which have flange pressure tappings must meet following conditions:
d > 12.5 mm
50 mm < D < 1000 mm
0.1 < β < 0.75
ReD > 5000 and ReD > 170xβ2xD
What happens if a calculation is not within these limits?
If the orifice plate properties or flow conditions are not according to the ISO 5167-2 calculator displays the message. If you want to do calculation regardless of the limitations in the standard, you can choose not to use ISO constraints in the calculation.
Register account and unlock full access
Desktop App
Fast. Accurate. Reliable.
Features in desktop app
- Save/Open multiple results
- Export to Word and Excel
- Print results
- Create list of custom fluid properties
- Resistance factor K for valves/fittings
- Pipe surface roughness selection
- Pipe material selection
- Gauge vs absolute pressure toggle
- Compressible isothermal flow
- Dry air isothermal flow
- Gas offtake flow
- Natural gas flow
- No admin rights required to install
Need a helping hand?
Powered by natural intelligence - NI
If you need a quick calculation, but you are not still familiar how to use the calculator, you can order calculation service from the calculator developer.